東応工業 ホームページ

東応工業株式会社のホームページへようこそ。

冷媒自動充填装置(IG/GCUシリーズ)<計量シリンダー方式>

東応工業株式会社の冷媒自動充填装置(IG/GCUシリーズ)を紹介するページです。

REFRIGERANT CHARGING EQUIPMENT(IG/GCU Series) <Measuring cylinder type>

The reliability being accumulated by the results for long years

冷媒自動充填装置(IG/GCUシリーズ)

SUMMARY

This equipment is designed to charge refrigerant accurately to refrigeration unit with measuring cylinder.

This system is designed to charge refrigerant after evacuation and vacuum leak check. All operation, display and settings are done with LCD touch panel.

FEATURES

  • Excellent endurance
  • High accurate charging
  • Wealthy cylinder size
  • Automatic temperature compensation(ATC)
  • Automatic temperature compensation(ATC) Backup function
  • Built-in backup function of each charging data
  • (CF card / production management-up / option)
  • Corresponding to each production management system
  • (Host PC, Bar-code, ID system, etc. / option)
  • Hydraulic oil mixing prevention :
  • Single piston cylinder:Hydraulic oil = Compressor oil
  • Double piston cylinder:Refrigerant piston and oil piston are separated
  • Elevation of easy maintenance

◎THE FIRST TOP OF THE PAGE

SPECIFICATIONS

Kinds of Refrigerant R-410A,R-407C,R-404A,R-134a,R-22,R-32,R-600a,R-290,R-744
(CO2)
, etc.
Single piston cylinder type
(Charging Accuracy)
300g
(±2g)
400g
(±3g)
700g
(±3g)
1000g
(±5g)
2000g
(±5g)
3200g
(±10g)
5000g
(±15g)
Double piston cylinder type
(Charging Accuracy)
300gDP
(±2g)
500gDP
(±3g)
1400gDP
(±5g)
2000gDP
(±5g)
5000gDP
(±15g)
 
 
Temperature Compensation Range 0〜50℃
Maximum Charging Capacity It is decided by a cylinder type
Rotary Encorder Resolution 0.025mm/1 pulse
Charging Speed MAX,250g/sec
Supply Air 0.4〜0.7MPa / 20〜402Nl/min
Consumption Power 4KVA
Vacuum Pump 300l/min
Measurement & Weight
(Single piston cyl)
1200W × 900D × 1700H / 700kg
Measurement & Weight
(Double piston cyl)
1200W × 900D × 2000H / 800kg
Applicable Law THE HIGH PRESSURE GAS SAFETY LAW

We can apply to all specifications (refrigerant kinds, charging capacity <Small minimum Large maximum>, accuracy, speed, vacuum pump , refrigerant supply method and production management system etc.)

◎REFRIGERANT CHARGING EQUIPMENT<MASS FLOW TYPE>

◎THE FIRST TOP OF THE PAGE